Skip to main content

Shot-noise Limited Faraday Rotation Spectroscopy for Detection of Nitric Oxide Isotopes in Breath, Urine and Blood

Author(s): Wang, Yin; Nikodem, Michal; Zhang, Eric; Cikach, Frank; Barnes, Jarrod; et al

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr1zw07
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWang, Yin-
dc.contributor.authorNikodem, Michal-
dc.contributor.authorZhang, Eric-
dc.contributor.authorCikach, Frank-
dc.contributor.authorBarnes, Jarrod-
dc.contributor.authorComhair, Suzy-
dc.contributor.authorDweik, Raed A-
dc.contributor.authorKao, Christina-
dc.contributor.authorWysocki, Gerard-
dc.date.accessioned2021-10-08T20:16:02Z-
dc.date.available2021-10-08T20:16:02Z-
dc.date.issued2015-08en_US
dc.identifier.citationWang, Yin, Nikodem, Michal, Zhang, Eric, Cikach, Frank, Barnes, Jarrod, Comhair, Suzy, Dweik, Raed A, Kao, Christina, Wysocki, Gerard. (2015). Shot-noise Limited Faraday Rotation Spectroscopy for Detection of Nitric Oxide Isotopes in Breath, Urine and Blood. Scientific Reports, 5 (1), 10.1038/srep09096en_US
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr1zw07-
dc.description.abstractMeasurement of NO and/or its metabolites in the various body compartments has transformed our understanding of biology. The inability of the current NO measurement methods to account for naturally occurring and experimental NO isotopes, however, has prevented the scientific community from fully understating NO metabolism in vivo. Here we present a mid-IR Faraday rotation spectrometer (FRS) for detection of NO isotopes. The instrument utilizes a novel dual modulation/demodulation (DM) FRS method which exhibits noise performance at only 2 times the fundamental quantum shot-noise level and provides the record sensitivity in its class. This is achieved with a system that is fully autonomous, robust, transportable, and does not require cryogenic cooling. The DM-FRS enables continuous monitoring of nitric oxide isotopes with the detection limits of 3.72 ppbv/Hz1/2 to 14NO and 0.53 ppbv/Hz1/2 to 15NO using only 45 cm active optical path. This DM-FRS measurement method can be used to improve the performance of conventional FRS sensors targeting other radical species. The feasibility of the instrument to perform measurements relevant to studies of NO metabolism in humans is demonstrated.en_US
dc.language.isoen_USen_US
dc.relation.ispartofScientific Reportsen_US
dc.rightsFinal published version. This is an open access article.en_US
dc.titleShot-noise Limited Faraday Rotation Spectroscopy for Detection of Nitric Oxide Isotopes in Breath, Urine and Blooden_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1038/srep09096-
dc.date.eissued2015-03-13en_US
dc.identifier.eissn2045-2322-
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
OA_Shot_noise_Limited_Faraday_Rotation_Spectroscopy.pdf980.51 kBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.