Skip to main content

Deep-inverse correlography: towards real-time high-resolution non-line-of-sight imaging

Author(s): Metzler, CA; Heide, F; Rangarajan, P; Balaji, MM; Viswanath, A; et al

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr17c1q
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMetzler, CA-
dc.contributor.authorHeide, F-
dc.contributor.authorRangarajan, P-
dc.contributor.authorBalaji, MM-
dc.contributor.authorViswanath, A-
dc.contributor.authorVeeraraghavan, A-
dc.contributor.authorBaraniuk, RG-
dc.date.accessioned2021-10-08T19:46:43Z-
dc.date.available2021-10-08T19:46:43Z-
dc.date.issued2020en_US
dc.identifier.citationMetzler, Christopher A., Felix Heide, Prasana Rangarajan, Muralidhar Madabhushi Balaji, Aparna Viswanath, Ashok Veeraraghavan, and Richard G. Baraniuk. "Deep-inverse correlography: towards real-time high-resolution non-line-of-sight imaging." Optica 7, no. 1 (2020): pp. 63-71. doi:10.1364/OPTICA.374026en_US
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr17c1q-
dc.descriptionCorrections: https://doi.org/10.1364/OPTICA.391291en_US
dc.description.abstractLow signal-to-noise ratio (SNR) measurements, primarily due to the quartic attenuation of intensity with distance, are arguably the fundamental barrier to real-time, high-resolution, non-line-of-sight (NLoS) imaging at long standoffs. To better model, characterize, and exploit these low SNR measurements, we use spectral estimation theory to derive a noise model for NLoS correlography. We use this model to develop a speckle correlation-based technique for recovering occluded objects from indirect reflections. Then, using only synthetic data sampled from the proposed noise model, and without knowledge of the experimental scenes nor their geometry, we train a deep convolutional neural network to solve the noisy phase retrieval problem associated with correlography. We validate that the resulting deep-inverse correlography approach is exceptionally robust to noise, far exceeding the capabilities of existing NLoS systems both in terms of spatial resolution achieved and in terms of total capture time. We use the proposed technique to demonstrate NLoS imaging with 300 µm resolution at a 1 m standoff, using just two 1/8th 𝑠 exposure-length images from a standard complementary metal oxide semiconductor detector.en_US
dc.format.extent63 - 71en_US
dc.language.isoen_USen_US
dc.relation.ispartofOpticaen_US
dc.rightsFinal published version. This is an open access article.en_US
dc.titleDeep-inverse correlography: towards real-time high-resolution non-line-of-sight imagingen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.1364/OPTICA.374026-
dc.identifier.eissn2334-2536-
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
DeepInverseCorrelographyImaging.pdf3.15 MBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.