Imaging the behavior of molecules in biological systems: breaking the 3D speed barrier with 3D multi-resolution microscopy
Author(s): Welsher, Kevin; Yang, Haw
DownloadTo refer to this page use:
http://arks.princeton.edu/ark:/88435/pr1rk5t
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Welsher, Kevin | - |
dc.contributor.author | Yang, Haw | - |
dc.date.accessioned | 2016-10-17T14:14:26Z | - |
dc.date.available | 2016-10-17T14:14:26Z | - |
dc.date.issued | 2015 | en_US |
dc.identifier.citation | Welsher, Kevin, Yang, Haw. "Imaging the behavior of molecules in biological systems: breaking the 3D speed barrier with 3D multi-resolution microscopy" Faraday Discuss., 184, 359 - 379, doi:10.1039/C5FD00090D | en_US |
dc.identifier.issn | 1359-6640 | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/pr1rk5t | - |
dc.description.abstract | The overwhelming effort in the development of new microscopy methods has been focused on increasing the spatial and temporal resolution in all three dimensions to enable the measurement of the molecular scale phenomena at the heart of biological processes. However, there exists a significant speed barrier to existing 3D imaging methods which is associated with the overhead required to image large volumes. This overhead can be overcome to provide nearly unlimited temporal precision by simply focusing on a single molecule or particle via real-time 3D single-particle tracking and the newly developed 3D Multiresolution Microscopy (3D-MM). Here, we investigate the optical and mechanical limits of real-time 3D single-particle tracking in the context of other methods. In particular, we investigate the use of an optical cantilever for position sensitive detection, finding that this method yields system magnifications of over 3000x. We also investigate the ideal PID control parameters and their effect on the power spectrum of simulated trajectories. Taken together, these data suggest that the speed limit in real-time 3D single particle-tracking is a result of slow piezoelectric stage response as opposed to optical sensitivity or PID control. | en_US |
dc.format.extent | 359 - 379 | en_US |
dc.language.iso | en_US | en_US |
dc.relation.ispartof | Faraday Discuss. | en_US |
dc.rights | This is the author’s final manuscript. All rights reserved to author(s). | en_US |
dc.title | Imaging the behavior of molecules in biological systems: breaking the 3D speed barrier with 3D multi-resolution microscopy | en_US |
dc.type | Journal Article | en_US |
dc.identifier.doi | doi:10.1039/C5FD00090D | - |
dc.date.eissued | 2015 | en_US |
dc.identifier.eissn | 1364-5498 | - |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Imaging the behavior of molecules in biological systems.pdf | 301.4 kB | Adobe PDF | View/Download |
Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.