Skip to main content

Nonuniform Line Coverage From Noisy Scalar Measurements

Author(s): Davison, Peter; Leonard, Naomi Ehrich; Olshevsky, Alex; Schwemmer, Michael

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr17872
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDavison, Peter-
dc.contributor.authorLeonard, Naomi Ehrich-
dc.contributor.authorOlshevsky, Alex-
dc.contributor.authorSchwemmer, Michael-
dc.date.accessioned2021-10-08T20:20:06Z-
dc.date.available2021-10-08T20:20:06Z-
dc.date.issued2015-07en_US
dc.identifier.citationDavison, Peter, Leonard, Naomi Ehrich, Olshevsky, Alex, Schwemmer, Michael. (2015). Nonuniform Line Coverage From Noisy Scalar Measurements. IEEE Transactions on Automatic Control, 60 (7), 1975 - 1980. doi:10.1109/TAC.2014.2375732en_US
dc.identifier.issn0018-9286-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr17872-
dc.description.abstractWe study the problem of distributed coverage control in a network of mobile agents arranged on a line. The goal is to design distributed dynamics for the agents to achieve optimal coverage positions with respect to a scalar density field that measures the relative importance of each point on the line. Unlike previous work, which implicitly assumed the agents know this density field, we only assume that each agent can access noisy samples of the field at points close to its current location. We provide a simple randomized protocol wherein every agent samples the scalar field at three nearby points at each step and which guarantees convergence to the optimal positions. We further analyze the convergence time of this protocol and show that, under suitable assumptions, the squared distance to the optimal coverage configuration decays as $O(1/t)$ with the number of iterations $t$, where the constant scales polynomially with the number of agents $n$. We illustrate these results with simulations.en_US
dc.format.extent1975 - 1980en_US
dc.language.isoen_USen_US
dc.relation.ispartofIEEE Transactions on Automatic Controlen_US
dc.rightsAuthor's manuscripten_US
dc.titleNonuniform Line Coverage From Noisy Scalar Measurementsen_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1109/TAC.2014.2375732-
dc.identifier.eissn1558-2523-
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
Nonuniform Line Coverage from Noisy Scalar Measurements.pdf368.19 kBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.