Skip to main content

Metrology and traceability of U–Pb isotope dilution geochronology (EARTHTIME Tracer Calibration Part I)

Author(s): Condon, Daniel J; Schoene, Blair; McLean, Noah M; Bowring, Samuel A; Parrish, Randall R

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr1wm13s8h
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCondon, Daniel J-
dc.contributor.authorSchoene, Blair-
dc.contributor.authorMcLean, Noah M-
dc.contributor.authorBowring, Samuel A-
dc.contributor.authorParrish, Randall R-
dc.date.accessioned2022-01-25T14:50:22Z-
dc.date.available2022-01-25T14:50:22Z-
dc.date.issued2015-09-01en_US
dc.identifier.citationCondon, Daniel J., Blair Schoene, Noah M. McLean, Samuel A. Bowring, and Randall R. Parrish. "Metrology and traceability of U–Pb isotope dilution geochronology (EARTHTIME Tracer Calibration Part I)." Geochimica et Cosmochimica Acta 164 (2015): 464-480. doi:10.1016/j.gca.2015.05.026.en_US
dc.identifier.issn0016-7037-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr1wm13s8h-
dc.description.abstractMixed 235U–233U–205Pb(–202Pb) tracers for U–Pb isotope-dilution isotope ratio mass spectrometry have been prepared under the auspices of the EARTHTIME Initiative. The methods and results for the preparation and calibration of the U/Pb ratio and isotopic abundances are given, and the various sources of uncertainty are discussed and quantified. The accuracy of the EARTHTIME U–Pb tracer isotopic composition can be traced back to SI units via a series of assay and isotopic composition reference materials combined with the experiments described herein. The parameters used in calculating U/Pb ratios (and inferentially U–Pb dates) have correlated uncertainties that result in a total uncertainty contribution to 206Pb/238U dates of ± < 0.03% (95% confidence). For suitable terrestrial materials such as zircon, when other sources of uncertainty have been minimised (e.g., open-system behaviour, 238U/235U variation, intermediate daughter product disequilibrium, common Pb, etc.) the U–Pb tracer calibration uncertainty is a limiting factor in the accuracy of U–Pb geochronology – but less so than the uncertainty in the 238U and 235U decay constants (±0.11 and 0.14% 2σ). The calibration approach of the mixed EARTHTIME 235U–233U–205Pb(–202Pb) tracers, in addition to updated values for reference materials (e.g., mixed gravimetric reference solutions), and parameters (e.g., Pb reference material assay), can be applied to other laboratory-specific U–Pb tracers and will facilitate the generation of accurate and directly inter-comparable U–Pb data.en_US
dc.format.extent464 - 480en_US
dc.language.isoen_USen_US
dc.relation.ispartofGeochimica et Cosmochimica Actaen_US
dc.rightsFinal published version. This is an open access article.en_US
dc.titleMetrology and traceability of U–Pb isotope dilution geochronology (EARTHTIME Tracer Calibration Part I)en_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1016/j.gca.2015.05.026-
dc.date.eissued2015-05-19en_US
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
Metrology_traceability_U-Pb_isotope_dilution_geochronology_EARTHTIME_Tracer_Calibration_I.pdf1.81 MBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.