Optical verification of occulter-based high contrast imaging
Author(s): Sirbu, D; Cady, EJ; Kasdin, NJ; Vanderbei, Robert J.; Lu, J; et al
DownloadTo refer to this page use:
http://arks.princeton.edu/ark:/88435/pr1p011
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sirbu, D | - |
dc.contributor.author | Cady, EJ | - |
dc.contributor.author | Kasdin, NJ | - |
dc.contributor.author | Vanderbei, Robert J. | - |
dc.contributor.author | Lu, J | - |
dc.contributor.author | Kao, E | - |
dc.date.accessioned | 2016-10-17T14:13:50Z | - |
dc.date.available | 2016-10-17T14:13:50Z | - |
dc.date.issued | 2011-09-15 | en_US |
dc.identifier.citation | Sirbu, D, Cady, EJ, Kasdin, NJ, Vanderbei, RJ, Lu, J, Kao, E. "Optical verification of occulter-based high contrast imaging" Proceedings of SPIE 8151, Techniques and Instrumentation for Detection of Exoplanets V, August 21, 2011, San Diego, California, 2011. doi:10.1117/12.894213 | en_US |
dc.identifier.issn | 0277-786X | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/pr1p011 | - |
dc.description.abstract | An external occulter precisely flown in formation with a space telescope has been recently studied as a mission scenario for direct imaging of exoplanets. 10-10 contrast must be attained to permit imaging of the faint reflected light of an Earth-like exoplanet. Here we report on experimental verification of a scaled occulter design that maintains a constant Fresnel number to an equivalent 400 mas space mission in monochromatic light at 632 nm using a diverging beam and an outer mask to suspend the occulter mask. We report contrast in regions of the discovery zone at 4.71 × 10-10 and suppression in the pupil plane of 3.7 × 10-7. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE). | en_US |
dc.relation.ispartof | Techniques and Instrumentation for Detection of Exoplanets V, August 21, 2011, San Diego, California | en_US |
dc.relation.ispartofseries | Proceedings of SPIE;815114 | - |
dc.rights | This is the publisher’s version of the article (version of record). All rights reserved to the publisher. Please refer to the publisher's site for terms of use. | en_US |
dc.title | Optical verification of occulter-based high contrast imaging | en_US |
dc.type | Conference Article | en_US |
dc.identifier.doi | doi:10.1117/12.894213 | - |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
VanderbeiSPIE8151-2011.pdf | 6.45 MB | Adobe PDF | View/Download |
Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.