Skip to main content

Atomic Magnetometer Multisensor Array for rf Interference Mitigation and Unshielded Detection of Nuclear Quadrupole Resonance

Author(s): Cooper, Robert J; Prescott, David W; Matz, Peter; Sauer, Karen L; Dural, Nezih; et al

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr1nh4m
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCooper, Robert J-
dc.contributor.authorPrescott, David W-
dc.contributor.authorMatz, Peter-
dc.contributor.authorSauer, Karen L-
dc.contributor.authorDural, Nezih-
dc.contributor.authorRomalis, Michael V-
dc.contributor.authorFoley, Elizabeth L-
dc.contributor.authorKornack, Thomas W-
dc.contributor.authorMonti, Mark-
dc.contributor.authorOkamitsu, Jeffrey-
dc.date.accessioned2018-07-20T15:10:45Z-
dc.date.available2018-07-20T15:10:45Z-
dc.date.issued2016-12en_US
dc.identifier.citationCooper, Robert J, Prescott, David W, Matz, Peter, Sauer, Karen L, Dural, Nezih, Romalis, Michael V, Foley, Elizabeth L, Kornack, Thomas W, Monti, Mark, Okamitsu, Jeffrey. (2016). Atomic Magnetometer Multisensor Array for rf Interference Mitigation and Unshielded Detection of Nuclear Quadrupole Resonance. PHYSICAL REVIEW APPLIED, 6 (10.1103/PhysRevApplied.6.064014en_US
dc.identifier.issn2331-7019-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr1nh4m-
dc.description.abstractAn array of four Rb-87 vector magnetometers is used to detect nuclear quadrupole resonance signals in an unshielded environment at 1 MHz. With a baseline of 25 cm, the length of the array, radio-frequency interference mitigation is also demonstrated; a radio-station signal is suppressed by a factor of 20 without degradation to the signal of interest. With these compact sensors, in which the probe beam passes through twice, the fundamental limit to detection sensitivity is found to be photon-shot noise. More passes of the probe beam overcome this limitation. With a sensor of similar effective volume, 0.25 cm(3), but 25 x more passes, the sensitivity is improved by an order of magnitude to 1.7 +/- 0.2 fT/root Hzen_US
dc.language.isoen_USen_US
dc.relation.ispartofPHYSICAL REVIEW APPLIEDen_US
dc.rightsFinal published version. Article is made available in OAR by the publisher's permission or policy.en_US
dc.titleAtomic Magnetometer Multisensor Array for rf Interference Mitigation and Unshielded Detection of Nuclear Quadrupole Resonanceen_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1103/PhysRevApplied.6.064014-
dc.date.eissued2016-12-27en_US
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
PhysRevApplied.6.064014.pdf1.33 MBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.