Skip to main content

Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector

Author(s): Boulay, MG; Camillo, V; Canci, N; Choudhary, S; Consiglio, L; et al

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr1b56d49h
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBoulay, MG-
dc.contributor.authorCamillo, V-
dc.contributor.authorCanci, N-
dc.contributor.authorChoudhary, S-
dc.contributor.authorConsiglio, L-
dc.contributor.authorFlammini, A-
dc.contributor.authorGalbiati, Cristiano-
dc.contributor.authorGhiano, C-
dc.contributor.authorGola, A-
dc.contributor.authorHorikawa, S-
dc.contributor.authorKachru, P-
dc.contributor.authorKochanek, I-
dc.contributor.authorKondo, K-
dc.contributor.authorKorga, G-
dc.contributor.authorKuźniak, M-
dc.contributor.authorKuźwa, M-
dc.contributor.authorLeonhardt, A-
dc.contributor.authorŁęcki, T-
dc.contributor.authorMazzi, A-
dc.contributor.authorMoharana, A-
dc.contributor.authorNieradka, G-
dc.contributor.authorPaternoster, G-
dc.contributor.authorPollmann, TR-
dc.contributor.authorRazeto, A-
dc.contributor.authorSablone, D-
dc.contributor.authorSworobowicz, T-
dc.contributor.authorSzelc, AM-
dc.contributor.authorTürkoğlu, C-
dc.contributor.authorWang, H-
dc.date.accessioned2024-05-03T18:23:24Z-
dc.date.available2024-05-03T18:23:24Z-
dc.date.issued2021-12-13en_US
dc.identifier.citationBoulay, MG, Camillo, V, Canci, N, Choudhary, S, Consiglio, L, Flammini, A, Galbiati, C, Ghiano, C, Gola, A, Horikawa, S, Kachru, P, Kochanek, I, Kondo, K, Korga, G, Kuźniak, M, Kuźwa, M, Leonhardt, A, Łęcki, T, Mazzi, A, Moharana, A, Nieradka, G, Paternoster, G, Pollmann, TR, Razeto, A, Sablone, D, Sworobowicz, T, Szelc, AM, Türkoğlu, C, Wang, H. (2021). Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector. The European Physical Journal C, 81 (12), 10.1140/epjc/s10052-021-09870-7en_US
dc.identifier.issn1434-6044-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr1b56d49h-
dc.description.abstract<jats:title>Abstract</jats:title><jats:p>A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers, one of which is equipped with polyethylene naphthalate (PEN) and the other with tetraphenyl butadiene (TPB) wavelength shifter. Both chambers are lined with enhanced specular reflectors and instrumented with SiPMs with a coverage fraction of approximately 1%, which represents a geometry comparable to the future large scale detectors. We measured the light yield of the PEN chamber to be  39.4<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>0.4(stat)<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>1.9(syst)% of the yield of the TPB chamber. Using a Monte Carlo simulation this result is used to extract the wavelength shifting efficiency of PEN relative to TPB equal to 47.2<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>5.7%. This result paves the way for the use of easily available PEN foils as a wavelength shifter, which can substantially simplify the construction of future liquid argon detectors.</jats:p>en_US
dc.languageenen_US
dc.relation.ispartofThe European Physical Journal Cen_US
dc.rightsFinal published version. This is an open access article.en_US
dc.titleDirect comparison of PEN and TPB wavelength shifters in a liquid argon detectoren_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1140/epjc/s10052-021-09870-7-
dc.date.eissued2021-12-13en_US
dc.identifier.eissn1434-6052-
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
s10052-021-09870-7.pdf594.84 kBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.