Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector
Author(s): Boulay, MG; Camillo, V; Canci, N; Choudhary, S; Consiglio, L; et al
DownloadTo refer to this page use:
http://arks.princeton.edu/ark:/88435/pr1b56d49h
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Boulay, MG | - |
dc.contributor.author | Camillo, V | - |
dc.contributor.author | Canci, N | - |
dc.contributor.author | Choudhary, S | - |
dc.contributor.author | Consiglio, L | - |
dc.contributor.author | Flammini, A | - |
dc.contributor.author | Galbiati, Cristiano | - |
dc.contributor.author | Ghiano, C | - |
dc.contributor.author | Gola, A | - |
dc.contributor.author | Horikawa, S | - |
dc.contributor.author | Kachru, P | - |
dc.contributor.author | Kochanek, I | - |
dc.contributor.author | Kondo, K | - |
dc.contributor.author | Korga, G | - |
dc.contributor.author | Kuźniak, M | - |
dc.contributor.author | Kuźwa, M | - |
dc.contributor.author | Leonhardt, A | - |
dc.contributor.author | Łęcki, T | - |
dc.contributor.author | Mazzi, A | - |
dc.contributor.author | Moharana, A | - |
dc.contributor.author | Nieradka, G | - |
dc.contributor.author | Paternoster, G | - |
dc.contributor.author | Pollmann, TR | - |
dc.contributor.author | Razeto, A | - |
dc.contributor.author | Sablone, D | - |
dc.contributor.author | Sworobowicz, T | - |
dc.contributor.author | Szelc, AM | - |
dc.contributor.author | Türkoğlu, C | - |
dc.contributor.author | Wang, H | - |
dc.date.accessioned | 2024-05-03T18:23:24Z | - |
dc.date.available | 2024-05-03T18:23:24Z | - |
dc.date.issued | 2021-12-13 | en_US |
dc.identifier.citation | Boulay, MG, Camillo, V, Canci, N, Choudhary, S, Consiglio, L, Flammini, A, Galbiati, C, Ghiano, C, Gola, A, Horikawa, S, Kachru, P, Kochanek, I, Kondo, K, Korga, G, Kuźniak, M, Kuźwa, M, Leonhardt, A, Łęcki, T, Mazzi, A, Moharana, A, Nieradka, G, Paternoster, G, Pollmann, TR, Razeto, A, Sablone, D, Sworobowicz, T, Szelc, AM, Türkoğlu, C, Wang, H. (2021). Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector. The European Physical Journal C, 81 (12), 10.1140/epjc/s10052-021-09870-7 | en_US |
dc.identifier.issn | 1434-6044 | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/pr1b56d49h | - |
dc.description.abstract | <jats:title>Abstract</jats:title><jats:p>A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers, one of which is equipped with polyethylene naphthalate (PEN) and the other with tetraphenyl butadiene (TPB) wavelength shifter. Both chambers are lined with enhanced specular reflectors and instrumented with SiPMs with a coverage fraction of approximately 1%, which represents a geometry comparable to the future large scale detectors. We measured the light yield of the PEN chamber to be 39.4<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>0.4(stat)<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>1.9(syst)% of the yield of the TPB chamber. Using a Monte Carlo simulation this result is used to extract the wavelength shifting efficiency of PEN relative to TPB equal to 47.2<jats:inline-formula><jats:alternatives><jats:tex-math>$$\,\pm \,$$</jats:tex-math><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mspace /> <mml:mo>±</mml:mo> <mml:mspace /> </mml:mrow> </mml:math></jats:alternatives></jats:inline-formula>5.7%. This result paves the way for the use of easily available PEN foils as a wavelength shifter, which can substantially simplify the construction of future liquid argon detectors.</jats:p> | en_US |
dc.language | en | en_US |
dc.relation.ispartof | The European Physical Journal C | en_US |
dc.rights | Final published version. This is an open access article. | en_US |
dc.title | Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector | en_US |
dc.type | Journal Article | en_US |
dc.identifier.doi | doi:10.1140/epjc/s10052-021-09870-7 | - |
dc.date.eissued | 2021-12-13 | en_US |
dc.identifier.eissn | 1434-6052 | - |
pu.type.symplectic | http://www.symplectic.co.uk/publications/atom-terms/1.0/journal-article | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
s10052-021-09870-7.pdf | 594.84 kB | Adobe PDF | View/Download |
Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.