Skip to main content

Orientation Determination of Cryo-EM Images Using Least Unsquared Deviations

Author(s): Wang, Lanhui; Singer, Amit; Wen, Zaiwen

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr18j0j
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWang, Lanhui-
dc.contributor.authorSinger, Amit-
dc.contributor.authorWen, Zaiwen-
dc.date.accessioned2019-08-29T17:01:17Z-
dc.date.available2019-08-29T17:01:17Z-
dc.date.issued2013en_US
dc.identifier.citationWang, Lanhui, Singer, Amit, Wen, Zaiwen. (2013). Orientation Determination of Cryo-EM Images Using Least Unsquared Deviations. SIAM JOURNAL ON IMAGING SCIENCES, 6 (2450 - 2483. doi:10.1137/130916436en_US
dc.identifier.issn1936-4954-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr18j0j-
dc.description.abstractA major challenge in single particle reconstruction from cryo-electron microscopy is to establish a reliable ab initio three-dimensional model using two-dimensional projection images with unknown orientations. Common-lines-based methods estimate the orientations without additional geometric information. However, such methods fail when the detection rate of common-lines is too low due to the high level of noise in the images. An approximation to the least squares global self-consistency error was obtained in [A. Singer and Y. Shkolnisky, SIAM J. Imaging Sci., 4 (2011), pp. 543-572] using convex relaxation by semidefinite programming. In this paper we introduce a more robust global self-consistency error and show that the corresponding optimization problem can be solved via semidefinite relaxation. In order to prevent artificial clustering of the estimated viewing directions, we further introduce a spectral norm term that is added as a constraint or as a regularization term to the relaxed minimization problem. The resulting problems are solved using either the alternating direction method of multipliers or an iteratively reweighted least squares procedure. Numerical experiments with both simulated and real images demonstrate that the proposed methods significantly reduce the orientation estimation error when the detection rate of common-lines is low.en_US
dc.format.extent2450 - 2483en_US
dc.language.isoen_USen_US
dc.relation.ispartofSIAM JOURNAL ON IMAGING SCIENCESen_US
dc.rightsFinal published version. Article is made available in OAR by the publisher's permission or policy.en_US
dc.titleOrientation Determination of Cryo-EM Images Using Least Unsquared Deviationsen_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1137/130916436-
dc.date.eissued2013-12-03en_US
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
130916436.pdf1.54 MBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.