Test and Comparison of Photomultiplier Tubes at Liquid Argon Temperature
Author(s): Acciarri, R; Antonello, M; Boffelli, F; Cambiaghi, M; Canci, N; et al
DownloadTo refer to this page use:
http://arks.princeton.edu/ark:/88435/pr1673p
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Acciarri, R | - |
dc.contributor.author | Antonello, M | - |
dc.contributor.author | Boffelli, F | - |
dc.contributor.author | Cambiaghi, M | - |
dc.contributor.author | Canci, N | - |
dc.contributor.author | Cavanna, F | - |
dc.contributor.author | Cocco, AG | - |
dc.contributor.author | Di Pompeo, F | - |
dc.contributor.author | Fiorillo, G | - |
dc.contributor.author | Galbiati, Cristiano | - |
dc.contributor.author | Grandi, L | - |
dc.contributor.author | Kryczynski, P | - |
dc.contributor.author | Meng, G | - |
dc.contributor.author | Montanari, C | - |
dc.contributor.author | Palamara, O | - |
dc.contributor.author | Pandola, L | - |
dc.contributor.author | Perfetto, F | - |
dc.contributor.author | Mortari, GB Piano | - |
dc.contributor.author | Pietropaolo, F | - |
dc.contributor.author | Raselli, GL | - |
dc.contributor.author | Rossella, M | - |
dc.contributor.author | Rubbia, C | - |
dc.contributor.author | Segreto, E | - |
dc.contributor.author | Szelc, AM | - |
dc.contributor.author | Triossi, A | - |
dc.contributor.author | Ventura, S | - |
dc.contributor.author | Vignoli, C | - |
dc.contributor.author | Zani, A | - |
dc.date.accessioned | 2019-10-09T19:23:24Z | - |
dc.date.available | 2019-10-09T19:23:24Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.citation | Acciarri, R, Antonello, M, Boffelli, F, Cambiaghi, M, Canci, N, Cavanna, F, Cocco, AG, Di Pompeo, F, Fiorillo, G, Galbiati, C, Grandi, L, Kryczynski, P, Meng, G, Montanari, C, Palamara, O, Pandola, L, Perfetto, F, Mortari, GB Piano, Pietropaolo, F, Raselli, GL, Rossella, M, Rubbia, C, Segreto, E, Szelc, AM, Triossi, A, Ventura, S, Vignoli, C, Zani, A. (2012). Test and Comparison of Photomultiplier Tubes at Liquid Argon Temperature. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 37 (1087 - 1094. doi:10.1016/j.phpro.2012.02.451 | en_US |
dc.identifier.issn | 1875-3892 | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/pr1673p | - |
dc.description.abstract | The most recent development in the field of photomultipliers operating at liquid Argon temperature is the Hamamatsu R11065 with peak QE up to about 35% A set of these photomultipliers has been extensively tested within the R&D program of theWArP Collaboration. During these tests the Hamamatsu PMTs showed extremely good performance and a light yield around 7 phel/keV(ee) has been achieved in a Liquid Argon detector with a photocathodic coverage of 12%. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments. (C) 2012 Published by Elsevier B. V. Selection and/or peer review under responsibility of the organizing committee for TIPP 11. | en_US |
dc.format.extent | 1087 - 1094 | en_US |
dc.language.iso | en_US | en_US |
dc.relation.ispartof | PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011) | en_US |
dc.rights | Final published version. This is an open access article. | en_US |
dc.title | Test and Comparison of Photomultiplier Tubes at Liquid Argon Temperature | en_US |
dc.type | Conference Article | en_US |
dc.identifier.doi | doi:10.1016/j.phpro.2012.02.451 | - |
dc.date.eissued | 2012-10-02 | en_US |
pu.type.symplectic | http://www.symplectic.co.uk/publications/atom-terms/1.0/conference-proceeding | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1-s2.0-S1875389212018081-main.pdf | 284.46 kB | Adobe PDF | View/Download |
Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.