Skip to main content

Demonstration and comparison of photomultiplier tubes at liquid Argon temperature

Author(s): Acciarri, R; Antonello, M; Boffelli, F; Cambiaghi, M; Canci, N; et al

Download
To refer to this page use: http://arks.princeton.edu/ark:/88435/pr1vq8m
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAcciarri, R-
dc.contributor.authorAntonello, M-
dc.contributor.authorBoffelli, F-
dc.contributor.authorCambiaghi, M-
dc.contributor.authorCanci, N-
dc.contributor.authorCavanna, F-
dc.contributor.authorCocco, AG-
dc.contributor.authorDeniskina, N-
dc.contributor.authorDi Pompeo, F-
dc.contributor.authorFiorillo, G-
dc.contributor.authorGalbiati, Cristiano-
dc.contributor.authorGrandi, L-
dc.contributor.authorKryczynski, P-
dc.contributor.authorMeng, G-
dc.contributor.authorMontanari, C-
dc.contributor.authorPalamara, O-
dc.contributor.authorPandola, L-
dc.contributor.authorPerfetto, F-
dc.contributor.authorMortari, GB Piano-
dc.contributor.authorPietropaolo, F-
dc.contributor.authorRaselli, GL-
dc.contributor.authorRubbia, C-
dc.contributor.authorSegreto, E-
dc.contributor.authorSzelc, AM-
dc.contributor.authorTriossi, A-
dc.contributor.authorVentura, S-
dc.contributor.authorVignoli, C-
dc.contributor.authorZani, A-
dc.date.accessioned2019-10-09T19:23:39Z-
dc.date.available2019-10-09T19:23:39Z-
dc.date.issued2012-01en_US
dc.identifier.citationAcciarri, R, Antonello, M, Boffelli, F, Cambiaghi, M, Canci, N, Cavanna, F, Cocco, AG, Deniskina, N, Di Pompeo, F, Fiorillo, G, Galbiati, C, Grandi, L, Kryczynski, P, Meng, G, Montanari, C, Palamara, O, Pandola, L, Perfetto, F, Mortari, GB Piano, Pietropaolo, F, Raselli, GL, Rubbia, C, Segreto, E, Szelc, AM, Triossi, A, Ventura, S, Vignoli, C, Zani, A. (2012). Demonstration and comparison of photomultiplier tubes at liquid Argon temperature. JOURNAL OF INSTRUMENTATION, 7 (10.1088/1748-0221/7/01/P01016en_US
dc.identifier.issn1748-0221-
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/pr1vq8m-
dc.description.abstractLiquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photo-sensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photomultiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics K.K. Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these tests the Hamamatsu PMTs showed excellent performance and allowed obtaining a light yield around 7 phel/keV(ee) in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keV(ee) of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.en_US
dc.language.isoen_USen_US
dc.relation.ispartofJOURNAL OF INSTRUMENTATIONen_US
dc.rightsAuthor's manuscripten_US
dc.titleDemonstration and comparison of photomultiplier tubes at liquid Argon temperatureen_US
dc.typeJournal Articleen_US
dc.identifier.doidoi:10.1088/1748-0221/7/01/P01016-
dc.date.eissued2012-01-20en_US
pu.type.symplectichttp://www.symplectic.co.uk/publications/atom-terms/1.0/journal-articleen_US

Files in This Item:
File Description SizeFormat 
1108.5584v2.pdf2.27 MBAdobe PDFView/Download


Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.