Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope
Author(s): Wang, Shiang-Yu; Chou, Richard CY; Huang, Pin-Jie; Ling, Hung-Hsu; Karr, Jennifer; et al
DownloadTo refer to this page use:
http://arks.princeton.edu/ark:/88435/pr19z90b7m
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wang, Shiang-Yu | - |
dc.contributor.author | Chou, Richard CY | - |
dc.contributor.author | Huang, Pin-Jie | - |
dc.contributor.author | Ling, Hung-Hsu | - |
dc.contributor.author | Karr, Jennifer | - |
dc.contributor.author | Chang, Yin-Chang | - |
dc.contributor.author | Hu, Yen-Shan | - |
dc.contributor.author | Hsu, Shu-Fu | - |
dc.contributor.author | Chen, Hsin-Yo | - |
dc.contributor.author | Gunn, James E | - |
dc.contributor.author | Reiley, Dan J | - |
dc.contributor.author | Tamura, Naoyuki | - |
dc.contributor.author | Takato, Naruhisa | - |
dc.contributor.author | Shimono, Atsushi | - |
dc.date.accessioned | 2022-01-25T15:00:35Z | - |
dc.date.available | 2022-01-25T15:00:35Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.citation | Wang, Shiang-Yu, Chou, Richard CY, Huang, Pin-Jie, Ling, Hung-Hsu, Karr, Jennifer, Chang, Yin-Chang, Hu, Yen-Shan, Hsu, Shu-Fu, Chen, Hsin-Yo, Gunn, James E, Reiley, Dan J, Tamura, Naoyuki, Takato, Naruhisa, Shimono, Atsushi. (2016). Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope. GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VI, 9908 (10.1117/12.2232035 | en_US |
dc.identifier.issn | 0277-786X | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/pr19z90b7m | - |
dc.description.abstract | The Prime Focus Spectrograph (PFS) is a new optical/ near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10 microns. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5 microns error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a similar to 10 micron FWHM across the field for reasonable sampling of the point spread function. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016. In this report, the performance of the MCS components, the alignment and testing procedure as well as the status of the PFS MCS will be presented. | en_US |
dc.language.iso | en_US | en_US |
dc.relation.ispartof | GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VI | en_US |
dc.rights | Final published version. Article is made available in OAR by the publisher's permission or policy. | en_US |
dc.title | Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope | en_US |
dc.type | Conference Article | en_US |
dc.identifier.doi | doi:10.1117/12.2232035 | - |
pu.type.symplectic | http://www.symplectic.co.uk/publications/atom-terms/1.0/journal-article | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
990881.pdf | 1.19 MB | Adobe PDF | View/Download | |
00202_psisdg9908_990881.zip | 2.68 MB | Unknown | View/Download |
Items in OAR@Princeton are protected by copyright, with all rights reserved, unless otherwise indicated.